Wall Base & Top Extensions

Wall Base & Top Extensions

By default, all layers of a wall project between the Base Constraint and Top Constraint level. These levels can be offset using the Base Offset and Top Offset parameters. When a wall is selected there are some Instance parameters that are greyed out and can be tricky to access.


Base is Attached and Top is Attached checkboxes

These parameters automatically populate and indicate whether the wall is attach to another element at the Top or Bottom. Valid attachments include, reference planes, floors, & roofs.

To attach a wall, first select the wall, or multiple walls, and in the Modify Tab ► Attach Top/Base then select the element to attach to.

Note:

  • When a wall is attached at the Base or Top the checkbox will still be greyed out. This field is always automatically populated by Revit.

The process to undo the attachment is to select the wall and Detach Top/Base and then the attached element to be un-attached.

 


Base Extension Distance and Top Extension Distance

The selected wall below has 4 layers and any number of layers can be unlocked. Unlocking a layer enables the Base Extension Distance or Top Extension Distance parameter depending if you unlocked the Base or Top or both.

A wall with the Base Extension Distance parameter enabled

How to enable the Extension Distance Parameters

Base Extension Distance process
  1. Select the wall then in the Properties Palette choose Edit Type ► Edit Structure which opens the Edit Assembly dialog.

  2. Expand the Preview pane on the left, if it’s not already visible, by clicking on the <<Preview button.

  3. Ensure the View type is set to the Section view

  4. Zoom into the preview on the base or top, depending on which you want to enable.

  5. Select Modify Vertical Structure (Section Preview only) ► Modify

  6. In the Preview Pane, select the bottom/top shape handle of the layer you want to unlock.

  7. A padlock icon will show indicating whether this layer is currently constrained or unconstrained to the Base/Top of the wall. If you hover over the lock a tooltip will display “Unlock to make this region extendable”. Left click on the padlock to unconstrain it. You can unlock multiple adjacent layers.

  8. Collapse the Preview by selecting Preview >>

  9. Select OK to close the Edit Assembly dialog

  10. Select OK to close the Edit Type dialog

  11. All instances of this wall type now have the Base Extension Distance and/or Top Extension Distance parameters active. Each wall instance can be adjusted by

    1. Selecting the wall, or multiple walls and adjusting the Extension Distance instance parameter or

    2. Selecting the wall and dragging the 2nd blue push/pull arrow in Elevation/Section.

Warning:

  • Unlocked Layers must be adjacent or a warning will appear and prevent you from clicking OK

Workaround:

  • If you want the 2 outside layers to be unlocked you could reverse engineer it and unlock all the middle layers instead. It will have the same outcome but use different parameters.

  • If you require more than 2 heights for the different layers, then you would need to resort to detailing or using the Parts command.


Related articles